Victron Autotransformer 120/240VAC-32A
The Autotransformer: for step up, step down and split phase balancing
An autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.
Consider for example a 30A 120/240V split phase supply. The supply could be the grid, a generator or two stacked inverters. Some of the loads connected are 240V, others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected, the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer, for example, will draw 10A from one leg. A 120V washing machine could even draw in excess of 20A from one leg. Between the two legs the difference in current, or current unbalance, will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A, the other leg may be drawing no more than 10A, and increasing the 240V load, for example, will result in an overload of one leg while the other leg still has spare capacity.
| Versandgewicht: | 13,58 kg |
| Artikelgewicht: | 12,80 kg |
Dein zertifizierter Victron Energy Händler und Installateur
Dein Victron Energy Installateur und Händler
zertifizierter Victron Energy Vertriebspartner
Installateur: Autorisierter Installateur, der von Victron Energy-Händlern zugelassen und umfassend geschult ist, um deine Anforderungen perfekt in robuste Installationen umzusetzen. Die Dienstleistungen umfassen Design und (vor Ort) Installation, Konfiguration, Support und Wartung von (fortgeschrittenen) Systemen.
Victron Händler & Installateur
zertifiziertes Serviceteam & Onlineshop
Original Victron Produkte
Victron Service & Beratung
Victron Autotransformer 120/240VAC-32A
The Autotransformer: for step up, step down and split phase balancing
An autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.
Consider for example a 30A 120/240V split phase supply. The supply could be the grid, a generator or two stacked inverters. Some of the loads connected are 240V, others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected, the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer, for example, will draw 10A from one leg. A 120V washing machine could even draw in excess of 20A from one leg. Between the two legs the difference in current, or current unbalance, will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A, the other leg may be drawing no more than 10A, and increasing the 240V load, for example, will result in an overload of one leg while the other leg still has spare capacity.
| Versandgewicht: | 13,58 kg |
| Artikelgewicht: | 12,80 kg |
Dein zertifizierter Victron Energy Händler und Installateur
Dein Victron Energy Installateur und Händler
zertifizierter Victron Energy Vertriebspartner
Installateur: Autorisierter Installateur, der von Victron Energy-Händlern zugelassen und umfassend geschult ist, um deine Anforderungen perfekt in robuste Installationen umzusetzen. Die Dienstleistungen umfassen Design und (vor Ort) Installation, Konfiguration, Support und Wartung von (fortgeschrittenen) Systemen.
Victron Händler & Installateur
zertifiziertes Serviceteam & Onlineshop
Original Victron Produkte
Victron Service & Beratung